5.0.30
11/2/2026
Changes made for Pathfinder 5226 controllers.
Speed scaling bug fixed. GetSpeed returns a percent, not units per second. The MDI velocity now converts percent against EIP_MAX_VELOCITY, matching the Kinetix300 driver. Before this, 1% commanded a full unit per second and 100% saturated at p2571. False move-complete fixed. Move-complete is no longer evaluated while the move command is still pending through the reject/enable/activate handshake. That false completion dropped the framework to idle while the drive ran the move, so a jog release could not stop one backgauge. Intermediate-stop recovery. A new move now also rejects a task that was paused by HALT, not just an activated one. New error E479 "drive not in fieldbus control". Raised once per drive when ZSW1 bit 9 is zero after cyclic data is valid, covering the Startdrive control panel holding control, X150 not set to EtherNet/IP, or wrong telegram. Previously the framework waited silently in StateWaitForDriveEnable. Connection-loss handling. New EIP_Reset_Axis_On_Connection_Loss puts the axis back to StatePowerDown and clears In_Motion, Enable, Ready and the moving flags. StateRun and StateDecelerate bail out to that reset when cyclic data goes invalid instead of waiting forever and timing out with E112. E70 is now posted unconditionally on loss, since the old queue-empty gate hid it behind the later E112. New MAX_TIME_TO_STOP_EIP_AXIS of 10 seconds. Stop_Moving_Axis uses it for EtherNet/IP axes because the drive ramps down on its own p2573 and the 2 second hydraulic timeout was too short. Header and comment clarifications. MDI_ACC/MDI_DEC are documented as percent overrides of p2572/p2573, with a new S210_MDI_RAMP_100PCT constant of 16384.0 replacing the old 1000000.0 "absolute" default for telegram 112. A bench-verify note says to change that one constant if the drive wants 100.0 instead. The normal-stop case gained a comment explaining why HALT must not be substituted.
Changes made for Pathfinder 5226 controllers.
BG2 decides its own finger offset from its own target using the BG1 finger parameters. On tapered parts BG2 previously inherited BG1's offset even when outside the threshold, which pushed BG2 past max position. BG2 raises or lowers its own finger output on the same rule as BG1. Position-limit check now tests the axis target after finger offsets rather than the raw argument, so an offset-extended target past the limit is refused with E192 instead of moved to. Finger-two state follows finger-one state when paired. Jog sets and clears finger two alongside finger one, the finger cleanup path always clears finger two when paired, and the finger-two reported position offset follows the finger-one state so it cannot get stuck. Reported backgauge positions compare the finger-adjusted value against the last sent value, so an offset applied or cleared while the axis stands still still reaches Pathfinder. Parallel backgauge jog launches both drives together. New bStartAxisDeferWait flag lets Start_Axis_Moving issue both move commands before waiting on either. On the EIP side, a paired backgauge holds its move until the other has finished enabling so both commands go out in the same pass.
Changes made for Pathfinder 5226 controllers.
Simulated BG2 rear limit, front limit and home inputs added, mirroring BG1. BG2 raw position is now seeded at its minimum on simulation start instead of a stale MRAM value.