4.13.18.2754
2/25/2020
A change has been made to Pathfinder to clarify the shear position display. Instead of displaying a simulated position, the shear position will be displayed in terms of time.
A new feature has been introduced to Pathfinder to alleviate positioning issues with mechanically-dependent axes by accounting for movement that is invisible to the feedback device. A dependent axis offset table models the relationship between an independent axis and its dependent axis. The table consists of a mapping from absolute positions to relative position offsets. The table is sent to the controller, which uses it to correct the reported position and positioning targets for the dependent axis. Pathfinder also uses the table when performing a Modify Offset operation. When setting up a machine, the independent axis must be referenced first. Currently, the only supported table type is a Radius Adjust to Clamping Beam Offset Table.
A change has been made to Pathfinder to display the hydraulic oil temperature in the axis position display when the machine has a temperature sensor.
- Jorns Twinmatic backgauge calibration updated
- Backgauge home limit input removed from ASCV2 and ASCV2HeavyDuty configurations
- Radius Adjust to Clamping Beam Offset Table added to ASCV2 and ASCV2HeavyDuty configurations
- Clamp calibration updated in ASCV2 and ASCV2HeavyDuty configurations
- Added Parameter 332 - Maximum LBB to Move CB - to JornsRabco and RoperWhitneyElectric configurations
- Added Parameter 159 - Minimum CB to Move Backgauge - to RoperWhitneyElectric configuration
- Added new ThalmannThakoV2OrigServo configuration
- Added homing direction for backgauge and bending beam to ASCV2HeavyDuty configuration
- Added new JornsFlexAnalog configuration