5.1.60.3812
11/18/2026
Changes made for Pathfinder V5 PC's.
The Clamp Sync machine option is defaulted to on for Jouanel models PTS/ PTU 2140, 2635, 3130, 4120.
Changes made for Pathfinder V5 PC's.
Pathfinder now asks a couple of questions about the machine's hardware the first time it starts on a Jouanel PTS, Jouanel PGL, Jorns Flex or Jorns Flex Analog configuration, and wires up the controller to match the answers. You no longer need a different configuration file or hand edits for a retrofit backgauge drive.
Jouanel PTS and PGL
Pathfinder asks "Backgauge drive: Analog or EtherNet/IP?" Analog is the default. Machines already in the field keep running exactly as before after the update. Jorns Flex and Flex Analog
Pathfinder asks "Backgauge drive: EtherNet/IP, Inverter or Servo?" EtherNet/IP is the default, which is what these machines ship with. Nothing changes for an existing machine unless you pick something else. Picking Inverter or Servo sets the backgauge up as a closed-loop analog axis on controller port 4 for both the encoder and the analog output. Inverter is 0 to 10 V, Servo is ±10 V. The I/O the analog drive needs is assigned automatically: Pin Function Input 14 Backgauge front limit (inverted) Input 15 Backgauge rear limit (inverted) Input 16 Backgauge home limit (inverted) Input 21 Inverter fault Output 20 Backgauge enable Output 21 Backgauge forward Output 22 Backgauge reverse The backgauge drive tuning parameters (PID gains, max velocity, deadband, homing direction, and so on) are now in the base configuration for both Flex files, so they are available to adjust once an analog drive is selected. Flex Analog only: light outputs
On a Flex Analog, outputs 20 to 22 are normally the Clamped, Flip and Rotate indicator lights. An inverter or servo backgauge needs those same three outputs, so a machine cannot have both. Pathfinder asks "Light outputs: Installed or Not installed?" Installed is the default. If you pick Inverter or Servo for the backgauge, Pathfinder will not ask about the lights and sets them to Not installed on its own. If you pick EtherNet/IP, you get the light question. If someone edits the Install file by hand into a forbidden combination, Pathfinder refuses to start and says which two settings clash. Where the answers live
The answers are saved in the machine's *.ConfigurationOverrides.Install.json file next to the other install-time settings, so they survive updates and come along with a backup. Machines upgraded from an older Pathfinder get the default answers filled in automatically, so no prompt appears and nothing changes on the machine. To change an answer later, remove the matching entry from the Install file and restart Pathfinder. It will ask again. What to check on a bench or at install
After choosing Inverter or Servo on a Flex, open the I/O screen and confirm the inputs and outputs above show the backgauge functions, and that the lights are gone on a Flex Analog. The prompts are in English, German and French. The German and French text is a draft awaiting review in Localazy, so until it is uploaded and approved those machines show English for these prompts.
Changes made for Pathfinder V5 PC's.
Parameter 714 ("Add Second Bend on Inside Hem Close") was dead code: it was still shipped in every config, but since a 2020 change nothing read it. The second-bend behaviour had been moved to parameter 754, Middle Hem Mode, and only fired on middle hems.
I restored 714 so that setting it to Yes adds a second small bend after the first bend of any closed hem that will be closed inside the machine, regardless of where the hem sits on the part. The second bend is the same one the middle-hem path produces: 40 degrees at the backgauge offset minus 0.250 inch. The middle-hem path is unchanged.
Two files changed: the parameter collection gets its ShouldAddSecondInsideHemBend flag back, and the operation builder checks it alongside the middle-hem flag, using a small helper that reads the inside or outside choice from the hem's close step.