XL2CL
5.111.0
10/21/2026
XL200 X.111.0 released

All XL200 controllers

Enhancements

SCN 5419: XL2; DIP switch 32 support

DIP Switch 32 - making the 32nd configuration switch usable and displayed correctly

The XL200's configuration "switches" are stored as a 32-bit number, and switch 32 is the very top bit of that number. Until now switch 32 could not really be used: its checkbox on the switch configuration screen was disabled, and because it is the top bit, turning it on made the whole switch value appear as a negative number - on the switch screen, on the System Information and Model Information screens, and in the value the controller sends up to Eclipse.

This change enables the switch 32 checkbox (on Closed Loop controllers) and makes the controller treat and display the switch value as a normal positive number everywhere it is shown or sent. With this in place, switch 32 can be set and read correctly.

This is generic groundwork - it does not by itself change how any machine runs. It simply makes the 32nd switch available and trustworthy for any feature that needs it.

Bug Fixes

SCN 5416: XL2; Manual Shear while in the Run Mode halts the line.

This bug was introduced in software versions V5.92.00 and V4.92.00 when the Open and Closed Loop source code was merged together.

While in the Run Mode, if the Manual Shear input is activated on a machine that does not support it, the line will halt when the run input is released.

This has been resolved.

SCN 5418: XL2; Diagnostic logger string indexing bug.

The logger class, in some case, uses a char array element as an index into the array, which works fine, provided the char value is below 128. A char variable is a signed variable and 128 is interpreted as a negative value in a signed char. This indexed the array out of bounds.

The logger class is typically only active while debugging and strings this large are not typically used for logging. It is unlikely to have caused any issues in the field but has been fixed nonetheless.

XL2CL only

Other Changes

SCN 5420: XL2CL; Press Down Only switch configuration for MHA DAs

Patriot Press Down-Only Mode (MHA and MHA2) - fit more presses on one drive

Patriot press controllers - both the single-drive "MHA" and the dual-die "MHA2" - can now be set to a "down-only" press mode. Normally each press drives a "down" output and a separate "up" (retract) output, and waits for both a "press complete" and an "up complete" signal. In down-only mode, each press uses only its down output and a single press-complete signal.

Because that uses half the inputs and outputs, one drive can control up to eleven presses, where the up/down pair previously limited it to six. The mode is selected with DIP switch 32 and was added for a customer who needs more than six presses on a dual-die Patriot. It works on single-press machines too, and it does not change how many "gag" outputs are provided.

The Press Information diagnostic screen was also rebuilt to group the presses under each die (plus any "open loop" presses that have no die), so machines with the higher press counts this feature allows show all of their presses clearly instead of running off the edge of the screen.