XL2OL
5.112.0
10/30/2026
XL200 X.112.0 released

All XL200 controllers

Enhancements

SCN 5428: XL2; Stacker Count Setting

A customer requested the ability to see and edit the number of parts on the Stacker. A Stacker Count setting was added to setups to show and allow the edit of the number of parts on the Stacker. The setting is updated in the Setup screen when it is incremented or cleared while running parts or by a Manual Stack operation.

This is a state variable, not a setting that is restored by Eclipse.

Bug Fixes

SCN 5427: XL2; Remote IO thread corrupts Eclipse Task thread

The Remote IO thread, used for the Scottsdale app, has the potential to corrupt the Eclipse Communication thread, which could in turn cause the Eclipse thread to reinit the EtherNet port. A reconfiguration of the ethernet port can then cause the Remote IO communication to fail.

The actual results of the corruption are just theoretical, but the corruption is real and needed to be fixed.

XL2CL only

Enhancements

SCN 5423: XL2CL; CL Data Encoder Scaling Changes

Closed Loop Data Screen Graph — Encoder Scaling and Flat-Trace Corrections

The Data screen graph on the Closed Loop diagnostics display draws the motor command together with the motor and material encoder feedback so they can be compared on one chart. Two problems with the way the encoder traces were drawn have been corrected.

First, the encoder traces are now scaled to the command by matching the total amount of motion over the captured move, instead of by lining up a single peak. The old method lined up the tallest point of each trace, which could place a trace too high or too low whenever that peak did not line up cleanly with the command — for example when the motor was following with some lag, when there was mechanical backlash in the drive train, or when the captured move was short. Scaling by total motion makes the traces line up correctly regardless of lag, so an encoder that is tracking the command properly now overlays it as expected, and one that is genuinely running ahead or behind stands out clearly.

Second, the graph no longer flattens an encoder trace that is actually moving. On a slow jog the encoders advance only a few counts at a time, and the previous logic discarded those small counts and drew the trace as a flat line even though the axis was moving. The graph now adds up the motion across the whole capture and only treats an encoder as inactive when it shows essentially no travel — less than about a quarter inch — over the entire capture. An encoder that receives no counts at all, such as a disconnected or unused second encoder, still reads as a flat line, which is correct.

The direction of each trace is preserved, so an encoder that counts opposite to the command still plots in the opposite direction and remains easy to spot.

These changes affect only the diagnostic graph. Machine motion and control are not changed.

Bug Fixes

SCN 5422: XL2CL; CL Data Screen, displayed command value flips sign in the graph

Closed Loop Data Screen — Command Trace Reads the Wrong Direction Near Full Scale at about 95%.

On the Closed Loop Data diagnostic screen, the command trace could suddenly jump to the opposite side of the graph — reading near full negative when the command was actually near full positive, or the reverse — whenever the command reached or came close to 100%. This was strictly a display problem in how the graph prepared the command value for plotting; the actual command sent to the servo drive was always correct and properly limited. Because the graph showed a large value in the wrong direction, it was easy to misread and assume the machine was doing something it was not.

This has been corrected. The command trace now holds flat at the top or bottom of the graph when the command is at its limit, matching the real command, instead of flipping to the opposite side. The motor and material encoder traces are unchanged, and nothing about machine operation is affected.

Technically, the graph stores the command as a signed 16-bit value (about plus or minus 32767, representing plus or minus 100 percent) and runs it through a smoothing filter that temporarily scales the value up internally for precision. Near full scale, the filter's internal running value reaches roughly 1.1 billion, and the filter then adds two of those together; that sum (about 2.3 billion) exceeds the roughly 2.1 billion limit of a signed 32-bit number, so it rolls over to a large negative value and the plotted trace flips to the opposite side. The fix reduces that internal scale factor so the sum stays well within 32-bit range, and separately caps the stored command at its full-scale limit so the top value cannot roll a 16-bit number over by a single count. Neither change alters the filter's output level or the command the drive actually receives.

SCN 5426: XL2CL; Encoder Backlash Simulation

Closed Loop PC Simulator — Backlash Simulation Fixes

The Closed Loop PC simulator includes an optional backlash simulation used during development to reproduce the effect of mechanical slack and motor-follower lag in the drive train, so loop tuning and the feed-forward feature can be evaluated without a machine. Two defects in that simulation have been corrected.

The simulated delayed encoder signal was being generated from a running total rather than from the individual per-sample movements. With any appreciable amount of simulated delay this let the delayed value grow without bound and eventually reverse sign, so the simulated feedback would invert and the control loop would behave erratically. The simulation now delays the individual per-sample movements, which keeps the values bounded and correct at any delay setting.

In addition, the delayed-encoder buffer was not cleared between moves. Leftover movement data from the previous move — or from a setting that had since been changed — would be played back at the start of the next move, causing the simulated feedback to begin inverted. The buffer is now cleared between moves so each move starts from a clean state, matching the behavior seen right after startup.

The backlash simulation remains turned off by default and has no effect on normal operation; these corrections apply only when it is explicitly enabled for development testing. No shipped machine behavior is changed.