2763
Start Match Limits on Crank Shear
XL200
When the Eccentric Die was added to the MRE and MRE2 controllers the lower limit on Start Match position was changed from Die Travel(Auto)/8 to Die Travel(Auto)/4. This change was not backwards compatible with the default settings on the Crank and it also left existing installations with settings that would not pass the limits test. For the Crank Shear the lower limit on Start Match Position is changed back to Die Travel(Auto)/8.
| Model | Version | Released |
|---|---|---|
| XL2CL | 4.32.00 | 7/15/2015 |
| XL2CL | 3.69.00 | 7/15/2015 |