4264
5226; New Logic for When to Turn Off Throttle Bypass Output
Pathfinder

Changes made for Pathfinder 5226 controllers.

Some folding machines have a throttle valve that restricts the flow of fluid to force the axes to move a certain slower speed. On some Jorns machines there is a valve that when turned on will bypass the throttle valve and allow faster controlled movement. To make sure the machine is not always moving in slow because the controller is not bypassing the throttle valve the Throttle Bypass output was created. For more information refer to:

SCN 4172 - 5226; Added Throttle Bypass Output and Logic

Previous logic for this output was to always turn it off when the clamp slow speed limit is on and the clamp is moving in slow. Now FoldGuard Active also has to not be on to clear this output.

Model Version Released
5226BB 4.02.07 2/18/2020