4266
XL2CL; Home Switch Position range error bug on Crank/Eccentric Dies
XL200

The range test on the Home Switch Position for Crank/Eccentric Dies was invalid.

Some valid positive values were not being allowed.

The valid range for the Home Switch Position is any value between +- Die Travel (Auto) as long as it is also outside of the Start Match to Stop Match Position Range.

Model Version Released
XL2CL 5.80.00 11/30/2021
XL2CL 4.66.04 2/19/2020