4339
XL2; AMS Generic Driver improvments
XL200
All communication was modified to allow the printer 500msec to respond.
The 6370 was not responding to a protocol version request from the printer due to an unneeded carriage return in the command string interfering with the 6370 command communication.
The Ams Generic interface version command was modified to allow the response of "1" to be equivalent to "1.00". The printer is no longer required to send the ".00" part of the version number.
If Eclipse does not send the point size, the point size will default to 14 as the spec says.
The Clear Print Queue and Check Status commands were waiting for too many characters.
| Model | Version | Released |
|---|---|---|
| XL2OL | 5.80.00 | 11/30/2021 |
| XL2CL | 5.80.00 | 11/30/2021 |
| XL2OL | 4.69.00 | 8/24/2020 |
| XL2CL | 4.69.00 | 8/24/2020 |
| XL220OL | 4.70.00 | 9/30/2020 |
| XL220CL | 4.70.00 | 9/30/2020 |