4476
XL2OL; Missed Shear Error when stitching parts
XL200
The reported error occurred on an XL200I controller with switch setting 102.
The Following settings were used: Min Auto Stitch Length - 48.000" Max Auto Stitch Length - 65.000" Minimum Slow Distance 10.000" Shear and Punch Dwells - 1.0sec
Programmed 4 pieces @ 16.000"
On the PC simulation the controller would stop with a memory access error caused by using a NULL Pointer. This type of error is not detected on the Controller Hardware. The results of using a NULL pointer are not entirely predictable. It is very likely in the customers case it ultimately resulted in a Missed Shear Error.
There was a bug in the code that only occurred if more than two parts were stitched together. This has been resolved.
| Model | Version | Released |
|---|---|---|
| XL2OL | 5.80.00 | 11/30/2021 |
| XL2OL | 4.73.01 | 3/31/2021 |
| XL2CL | 4.73.01 | 3/31/2021 |
| XL2CL | 5.80.00 | 11/30/2021 |