A customer needed Multiple Presses defined on a Die Accelerator in the XL244XL. Each die may have additional presses configured for it using the following Switch settings.
Dip 25 Dip 24 Additional Presses on Die 1 Off Off 0 Off On 1 On Off 2 On On 3
Dip 27 Dip 26 Additional Presses on Die 2 Off Off 0 Off On 1 On Off 2 On On 3
These Switch settings require and utilize presses that are enabled using the existing Switch settings defined with Switches 4, 5 and 6.
Additional Presses for Die 1 start at Press 1. The first press and additional presses for Die 2 starts with the next remaining press after the presses defined on Die 1. Open Loop presses start with the next remaining press after the last press on Die 1, or Die 2, if enabled.
| Model | Version | Released |
|---|---|---|
| XL2CL | 5.85.00 | 6/22/2022 |
| XL2CL | 4.85.00 | 6/22/2022 |