XL2; Tail Out Configuration when set to Single not working properly
XL200

When the Dual Line Encoder option is enabled and the Tail Out Configuration is set to Single encoder, the Main encoder is supposed to be used all the time. Setting the Main Encoder to Exit(1) would not work, only the Entry (2) encoder was being used. This was resolved.

Some other changes were made related to tailing out and tailing in, based on which encoder is being used.

When the Main Encoder is set to Entry (2):

  1. Tail out is immediate.
  2. Thread up uses the Shear to Encoder Distance 2 to set the encoder
  3. Tail out uses the Shear to Encoder Distance 2 to calculate scrap.

When the Main Encoder is set to Exit (1)

  1. Tail out is delayed until the Shear Tail out Distance.
  2. Thread up uses the Shear Tail out Distance to set the encoder.
  1. Tail out uses the Shear Tail out Distance to calculate scrap.
Model Version Released
XL2OL 5.88.05 12/19/2022
XL2CL 5.88.05 12/19/2022
XL220OL 5.89.00 3/17/2023
XL220CL 5.89.00 3/17/2023
XL2OL 4.88.05 12/19/2022
XL2CL 4.88.04 12/17/2022
XL220OL 4.89.00 3/17/2023
XL220CL 4.89.00 3/17/2023