4744
XL2; Added Slow Run input for Open Loop material motion
XL200

The Closed Loop Feed to Stop controllers have a Slow Run input to help reduce Scrap when threading a new coil. It also helps for Material pit control.

Up until this point Open Loop controllers or controllers that have Open Loop Material motion control have handled with these things with external logic. However, if the material speed is controlled using the Analog feature of the controller, external logic is not sufficient.

This change adds an extended IO input (MODBUS) on input 52 or 50 for Open Loop Slow Run control. If the controller has Open Loop Material motion control, this input will be available.

HVAC Controllers use input 50.

All other controllers use input 52.

Model Version Released
XL2OL 5.89.00 3/17/2023
XL2CL 5.89.00 3/17/2023
XL220OL 5.89.00 3/17/2023
XL220CL 5.89.00 3/17/2023
XL2OL 4.89.00 3/17/2023
XL2CL 4.89.00 3/17/2023
XL220OL 4.89.00 3/17/2023
XL220CL 4.89.00 3/17/2023