XL200; Added (NTM) Option with Part Pause input
XL200

We are installing XL200 controllers on NewTech Machines with the intent of being a drop-in replacement for the MP465 controller. We have created a model option (NTM) for this purpose. The (NTM) option is only valid for the XL200 Open Loop controller.

The MP465 controller has a Remote Run input that functions like a Delay After Shear. After a Shear, if the Remote Run input is ON, the controller Delays After Shear forever. The delay timer, if configured, starts when the Remote Run input turns OFF or is OFF.

The XL has added this functionality to input 20 when the (NTM) option is enabled. The XL controller uses a different name for the input but otherwise functions identically. The input is called "Part Pause".

Model Version Released
XL2OL 5.92.00 2/2/2024
XL2OL 4.92.00 2/2/2024