4972
XL2CL; Lockups and resets with EtherCAT and SERCOS on second drive.
XL200
SCN 4952 - changed the timing on testing for drives to become fully enabled or disabling themselves.
This change worked on the first drive but relied on memory initialization that failed to work for subsequent drives. This resulted in an infinite loop of error messages that caused lockups and resets during memory test due to memory usage.
This same bug was present with EtherCAT and SERCOS enabled controllers. This has been resolved.
| Model | Version | Released |
|---|---|---|
| XL2OL | 5.95.03 | 11/15/2024 |
| XL2CL | 5.95.03 | 11/15/2024 |
| XL220OL | 5.96.00 | 12/10/2024 |
| XL220CL | 5.96.00 | 12/10/2024 |
| XL2OL | 4.95.03 | 11/15/2024 |
| XL2CL | 4.95.03 | 11/15/2024 |
| XL220OL | 4.96.00 | 12/10/2024 |
| XL220CL | 4.96.00 | 12/10/2024 |