5035
XL2; Simultaneous Press Up and Press Complete errors.
XL200
Simultaneous Press or Press Up Complete errors would not display.
Duplicate Error messages are filtered out in the user interface. Only the first instance gets dsiplayed, unless a flag to allow duplicates is used. The flag was not being used.
The second issue is that the press that is displayed was stored in a global variable, rather than a dynamic variable of some kind. This could lead to double, or more, reporting of the same press when multiple error messages are displayed, depending on the timing involved.
Both of these issues have been resolved.
| Model | Version | Released |
|---|---|---|
| XL2OL | 5.98.00 | 3/24/2025 |
| XL2CL | 5.98.00 | 3/24/2025 |
| XL220OL | 5.98.00 | 3/24/2025 |
| XL220CL | 5.98.00 | 3/24/2025 |
| XL2OL | 4.98.00 | 3/24/2025 |
| XL2CL | 4.98.00 | 3/24/2025 |
| XL220OL | 4.98.00 | 3/24/2025 |
| XL220CL | 4.98.00 | 3/24/2025 |