5160
XL2CL; KMF Settings
XL200

The KMF controller installs fleece on the bottom of roof pannels, based on the state of two hole detect inputs. There are no orders or data to collect. Eclipse is not enabled on these controllers.

According to AMS gmbh, these controllers have been configured with the same settings when they get installed. For that reason the following settings have had their default values modified to the values listed below.

Shear Dwell Down 0.25sec Press 1 Dwell Down 0.25sec Press 1 Dwell Up 0.05sec Tolerance 15mm Minimum Shear Distance 350mm Maximum Shear DIstance 620mm Minimum Press Distance 650mm Maximum Press Distance 750mm Reference Die on Manual Shear No Line Resolution 0.038418850mm Die Resolution 0.003820200mm Loop Gain 10.0 Jog Velocity 5MPM Reference Velocity 1MPM Max Die Return Velocity 60MPM Acceleration 900cm/s2 Enable Virtual Keyboard Yes Clear Queue After Prompt Dsiplay Format Metric mm. Jog Select Mode Die (Setting not visible)

This change will make setting up new installs easier and supporting customers who recieve software updates will have an easier time getting back up to speed.

Model Version Released
XL2CL 5.103.0 11/6/2025
XL2CL 4.103.0 11/6/2025