5198
Pathfinder; Clamping Beam Sync Feature and Status Flag
Pathfinder

Changes made for Pathfinder V5 PC's.

  • StatusResponseHelperTypes.cs - Added ClampingBeamSyncing = 0x00000080 to - StatusConditionFlags enum (replaced commented-out Unused flag)
  • StatusMessageType.cs - Added SyncingClampingBeam enum value
  • MachineCommunicationManager.cs - Added ClampingBeamSyncing flag check to set StatusMessageType.SyncingClampingBeam with status text; added SyncingClampingBeam case to Fire_StatusChanged switch
  • FormResource.resx (Main) - Added StatusSyncingClampingBeam = "Syncing Clamping Beam"

Error Messages

ErrorResource.resx - Added 4 error messages: E467_ClampingBeamSyncTimeout - "Clamping Beam Sync Timeout" E468_ClampingBeamSyncHeightExceeded - "Clamping Beam Sync Height Exceeded" E469_ClampingBeamSyncCompleteInputStuckOn - "Clamping Beam Sync Complete Input Stuck On" E470_ClampingBeamSyncIODefinitionError - "Clamping Beam Sync I/O Definition Error"

Generic Parameters (ParameterStoreList)

Added 3 parameters to all 8 Jouanel 5226 configurations, under ObjectName "Clamping Beam" (ObjectId 0x0066):

0x205D - Clamping Beam Sync Clear Timeout = 5000 0x205E - Clamping Beam Sync Complete Timeout = 10000 0x205F - Clamping Beam Sync Motion Timeout = 2000

Configurations updated: JouanelPTS33, JouanelPGL, JouanelPTL31, JouanelPTS24, JouanelPTS31, JouanelPTU31, JouanelHydraulicV2, JouanelPTS

Model Version Released
Pathfinder PC 5.01.34.3648 2/13/2026