Closed Loop Data Screen — Command Trace Reads the Wrong Direction Near Full Scale at about 95%.
On the Closed Loop Data diagnostic screen, the command trace could suddenly jump to the opposite side of the graph — reading near full negative when the command was actually near full positive, or the reverse — whenever the command reached or came close to 100%. This was strictly a display problem in how the graph prepared the command value for plotting; the actual command sent to the servo drive was always correct and properly limited. Because the graph showed a large value in the wrong direction, it was easy to misread and assume the machine was doing something it was not.
This has been corrected. The command trace now holds flat at the top or bottom of the graph when the command is at its limit, matching the real command, instead of flipping to the opposite side. The motor and material encoder traces are unchanged, and nothing about machine operation is affected.
Technically, the graph stores the command as a signed 16-bit value (about plus or minus 32767, representing plus or minus 100 percent) and runs it through a smoothing filter that temporarily scales the value up internally for precision. Near full scale the filter's internal running value reaches roughly 1.1 billion, and the filter then adds two of those together; that sum (about 2.3 billion) exceeds the roughly 2.1 billion limit of a signed 32-bit number, so it rolls over to a large negative value and the plotted trace flips to the opposite side. The fix reduces that internal scale factor so the sum stays well within 32-bit range, and separately caps the stored command at its full-scale limit so the top value cannot roll a 16-bit number over by a single count. Neither change alters the filter's output level or the command the drive actually receives.
| Model | Version | Released |
|---|---|---|
| XL2CL | 5.112.0 | 10/30/2026 |
| XL220CL | 5.112.0 | 10/30/2026 |
| XL2CL | 4.112.0 | 10/30/2026 |
| XL220CL | 4.112.0 | 10/30/2026 |