Changes made for Pathfinder 5226 controllers.
Change: allow fast clamp close under FoldGuard handshake (BlackBox, RunSingleBend.c)
Status: edited 2026-10-21, pending TFS checkin against changeset 4453. One file, five lines added, no lines removed.
Problem. On JornsFlex, and any other configuration that enables the FoldGuardWithHandshake feature group, the automatic clamp close always ran in slow speed from the top of the stroke. The FastSpeedSelect output never turned on, regardless of the FoldGuardActive or ClampingBeamSlowSpeedLimit input states.
Root cause. The handshake group maps FoldGuardActive, both EnableClampMoveDown inputs, ClampingBeamSlowSpeedLimit and the RequestClampMoveDown output, but it never assigns a pin to FoldGuardClampingBeamLaser. The clamp-close speed decision in RunSingleBend.c only consulted two inputs, ClampingBeamInhibited and FoldGuardClampingBeamLaser. With neither defined it always chose slow. That set the safe-speed flag, the discrete open-loop state machine started the move in its slow state, and that state has no transition back to fast. FoldGuardActive was consulted only to skip the safety-stop-height stop, never for speed. Jogging already treated FoldGuardActive as permission for fast, so jog and automatic behaved differently.
Fix. Added a third permitting term to the SlowSpeed expression at RunSingleBend.c:883-889. Fast is now allowed when FoldGuardActive is defined and on, and no FoldGuard laser input is defined. The two existing terms are unchanged.
Safety behaviour.
If a configuration maps the FoldGuard laser, the laser term still decides. A blocked laser is never overridden by FoldGuardActive. Slowing down remains the FoldGuard's responsibility through the ClampingBeamSlowSpeedLimit input. If it is on at move start the clamp starts in slow. If it turns on mid-move the existing handler issues a slow command, the loop drops to slow and the fast select clears on the next 1 ms cycle. Once slow, the clamp stays slow for the rest of that close. Automatic now matches the existing jog behaviour. Expected result on the machine. With FoldGuardActive on and the slow limit off, the clamp starts in slow for the configured slow-start time, then the fast select comes on until the slow distance or until the FoldGuard asserts the slow limit.
Not changed. The double-bend close in RunDoubleBend.c always passes safe speed and has no laser term, so HyperDrive and TwinPro handshake machines still close in slow. Left as is pending a decision.
| Model | Version | Released |
|---|---|---|
| 5226BB Rev F. | 4.04.32 | 11/2/2026 |
| 5226BB Rev G. | 5.00.31 | 11/2/2026 |
| 5226BB Rev H. | 5.01.07 | 11/2/2026 |