4.17.0.3054
10/12/2020
There was a bug in Pathfinder where the labels for the Clamp Open Height and Gripper Pressure fields in part handling steps would not be translated. This bug has been fixed.
A new feature has been added to Pathfinder that allows the user to pause while running a part. This is for cases where the operator wants to inspect the part and potentially open and re-close the clamp, such as on a hem smash, for example. This feature is engaged by checking the "Pause on Step" on a particular operation. This will cause the controller to stop motion but remain in run mode when that step is completed. Running the part can be resumed by the normal methods for initiating run.
There existed a bug in Pathfinder such that the serial number would not get populated under certain conditions when loading the Edge Settings view. This bug has been fixed.
- Added Parameter 311 - Clamp Positioning Tolerance - to JornsSingleBendFullRetrofitV2ClosedLoop configuration
- Removed backgauge enable output from ASCHydraulicV2 configuration
- Added new JornsSingleBendHydraulicUpgradeV1 configuration for single-bend machines outfitted with a double-folder hydraulic upgrade package