XL2CL
5.97.3
3/5/2025

This task error is generated if we get an extra IRQ7, which normally happens when recieve data is ready in the DSP or ARM co-processors.

The ARM co-processor API has the possibility to test if an IRQ7 interrupt is real. This is now being done on the ARM. Their may be a method to implement something similar for the DSP in the future.

If the interrupt is determined not to be real, we will leave the interrupt with no side effect and no longer generate the 8F000012 task error.

Hopefully this will resolve all cases of this issue.

SCN 5013 fixed an issue with the Die Stroke not being shortened on Press Completes on CLF Die Accelerators configured for multiple presses. An additional issue has now been found with the Press Complete tests that occur under the similar conditions.

To duplicate the issue, the master press on the Die needed to have a larger dwell than the slave presses. The Expect Press Complete setting needed to be configured for Yes on the master press. If the master press did not have a target and the slave press did, if its press dwell was shortened by a press complete, the master press would mistakenly report a Missing Press Complete error.

This has been resolved.