XLCL; Bogus Press Complete Error on a CLF configured with multiple presses.
XL200

SCN 5013 fixed an issue with the Die Stroke not being shortened on Press Completes on CLF Die Accelerators configured for multiple presses. An additional issue has now been found with the Press Complete tests that occur under the similar conditions.

To duplicate the issue, the master press on the Die needed to have a larger dwell than the slave presses. The Expect Press Complete setting needed to be configured for Yes on the master press. If the master press did not have a target and the slave press did, if its press dwell was shortened by a press complete, the master press would mistakenly report a Missing Press Complete error.

This has been resolved.

Model Version Released
XL2CL 5.97.03 3/5/2025
XL220CL 5.98.00 3/24/2025
XL2CL 4.97.03 3/5/2025
XL220CL 4.98.00 3/24/2025