4844
XL2; Add Minimum Slow Distance settings for Short and Very Short Parts
XL200

A request was made for separate Minimum Slow Distance settings applicable to the Short Part and Very Short Part settings.

There are two new settings, Short Part Min. Slow Dist. and Very Short Part Min. Slow Dist.. They have all the same properties as the Minimum Slow Distance setup.

The Short Part Min. Slow Dist. is used for Minimum Slow Distance when the part length is less than the Short Part Length.

The Very Short Part Min. Slow Dist. is used for Minimum Slow Distance when the part length is less than the Very Short Part Length.

For legacy systems where the user may not have configured the new setups, if the applicable setup has not been configured (Zero Length), the value in the Minimum Slow Distance setting will be used.

Model Version Released
XL2OL 5.91.00 12/8/2023
XL2CL 5.91.00 12/8/2023
XL220OL 5.92.00 2/2/2024
XL220CL 5.92.00 2/2/2024
XL2OL 4.91.00 12/8/2023
XL2CL 4.91.00 12/8/2023
XL220OL 4.92.00 2/2/2024
XL220CL 4.92.00 2/2/2024